Special
Features of Sanghi Oxygen Dissolved Acetylene Gas Plant
·
No bulky gas holder required.
·
Automatic controls for feeding water. Maintaining temperatures,
pressures, and slurry
drain are fool proof, efficient and are of international
standard.
·
Excellent absorption of gas in cylinders.
·
No gas loss and high yield.
·
Very simple and safe to operate.
·
Low power consumption.
·
Low maintenance cost.
·
Manufactured as per Designs & Drawings
Approved by the Chief Controllers of explosives
Govt of India
Process
Description Of Sanghi Oxygen
Acetylene Generator.
The
SANGHI Acetylene Generator is of an advanced design, incorporating
several features not ordinarily found in other generators. The SANGHI
Acetylene generator is a fully automatic plant. Pneumatically controlled
valves and highly sensitive sensors, integral with the temperature
control instruments, perform all operations. These in turn open
the water inlet valve or residue drain valve etc. Two hydraulic
pumps help to open and close the supply of calcium carbide, which
is fed into the generator by screw feed conveyors. The screw feed
mechanism and the agitators are operated by flameproof motors and
fittings. The entire operation is perfectly synchronized to give
maximum efficiency and simplicity in operation. Any failure, whether
it is of power supply, water or air is signaled visually and also
audibly when an alarm bell rings to alert the operator.
Only
flame proof lights & electrical fittings according to IS 214868
(group II) or BSS- 229 may be used in an acetylene plant building.
Acetylene cylinder must be of specification IS: 7312:1974 or ICC:
8.
Chemical
Purifier
This consists of two layers of regenerative
chemicals,which remove additional impurities. The purifying agent
may be reactivated for re-use by the atmosphere air. For continuous
operation one extra charge of chemicals can be kept in open wooden
trolley
Water
Scrubber
The equipment
is installed between the chemical
purifier and the high-pressure compressor which
helps to remove additional impurities from the gas if any.
Acetylene
Compressor
For filling of
the cylinders an I.R. make reciprocating, oil lubricated, multi-stage,
water submerged compressor with intercoolers, safety relief valve
for each stage, driven by a 15 H.P. Flame Proof Motor confirming
to IS: 2148-68 (Gr. II.B) is provided.
No Loss - Carbide charge
No
gas is lost or wasted while charging the carbide because that section
is completely sealed off from the generator by a high pressure hydraulically
operated valve.All the above controls are automatic and require
no attention from the operator. There is a further safety device,
in terms of an alarm bell, which will ring continuously till the
fault is corrected.
High Pressure Drier
This consists
of a battery of three high-pressure vessels. The first is filled
with metal filler, while the second and third are filled with anhydrous
calcium chloride. It is very important that the high pressure drier
is fully filled up with Calcium Chloride, as any voids in high-
pressure area are against the required safety.
Filling
Manifold
This
consists of a battery of 60 filling connections to connect to the
gas cylinders. Non- return valves are provided in various sections
of the pipeline to the filling manifold. These non- return valves
are extremely important for the safe operation of the plant and
should be periodically cleaned to remove rust and scales, (iron
cause fire). The cylinder filling pig tails (flexible hose pipes)
should also be periodically cleaned to ensure that they; do not
burst during filling operation, (if they do burst, a fire would
ensure due to sudden discharge of Acetylene).
Instrument
Air Compressor
A flameproof
motor with a buffer tank drives the instrument air compressor.
Technical
Data
Specifications
45
M3/Hr. Acetylene Plant
100
M3/Hr. Acetylene Plant
Efficiency
98%
98%
Capacity
45
M3/hr. Of Acetylene
100
M3/Hr. of Acetylene
Cylinder
filled per batch
60
Cylinders
120
Cylinders
Carbide
size
0
~ 80 mm
0
~ 80 mm
High
Pressure Control
If all the gas
generated cannot be drawn in by the compressor and passed on to
the filling manifold, either due to low capacity of the compressor
or fast generations, gas pressure will gradually build in the generator.
When the gas pressure reaches a predetermined level (about 0.5 kg
/cm2) carbide charging will be cut off automatically and further
generation of gas is stopped.
There is no expensive gasholder with the SANGHI Acetylene Generator.
This item alone will reduce the investment on such a plant. Further,
as the gas generated is always at a positive pressure, the pumping
cost is also reduced. Since the generator is constantly at a positive
pressure, (once the plant has been purged with Nitrogen) no air
enter the system, and it is this feature which makes "SANGHI"
Plant inherently very safe
Water Level Control
If excessive
water enters the generator to cool it and the water level goes above
the high level mark, the water-level control instrument will immediately
discharge the excessive water thus maintaining the water between
the acceptable high and low level marks.
Sanghi Purifying Mass & L K Mixture
A
mixture of purifying mass & L K Mixture is used to remove unpurities
such as Sulphur, Phosphorus, Arsenic, Ammonia etc. in the form of
hydrides such as Hydrogen sulphide, Phosphine etc. This chemical
is regnerative, can be used for several applications.
Sanghi-Weighing Scale:
Dial Scale 3205 CLE / COE Capacities: - 100, 200, 300, 500 &
1000 Kg. White pointer with black indicator to give shadowless line-to-line
(non-parallax) indication on 584 mm dia. Ready line . Scale mounted
on four wheels enclosed in a substantial cast iron frame. Tough,
dust proof and moisture proof housing to stand up to any conditions.
This ensures no rusting and no deterioration of the mechanism components.
Sanghi Acetone Pump :
It is a geared motor pump coupled with motor by love-joy coupling.
The pump has two parts mainly suction port and the discharge port.
The suction port is provided with extended pipe and foot value to
reach the bottom of the acetone drum.